MAINTENANCE
All the device's maintenance operations are exclusively aimed at qualifi ed staff.
EN
Make sure that the room's mains network is disconnected before carrying out maintenance operations.
Once installed, the product's components should be arranged as shown in the above image.
1) INDICATION OF MAINTENANCE PERIOD
We advise cleaning the fi lters (8) and the ceramic exchanger (7) every 3 months.
We advise changing the fi lters every 2 years. Contact your dealer for delivery of replacement fi lters.
1a) RESPIRO 100 N / RESPIRO 150 N
This version does not have an alarm for cleaning/replacement of fi lters.
1b) RESPIRO 100 RD N / RESPIRO 150 RD N
Every 2000 hours of operation the indicator light at the bottom right will emit a continuous red light signal. During the
alarm, each remote control, except for the fi lter reset combination, will be disabled. The product will continue to operate
with the last command received.
Clean the exchanger and the fi lters as specifi ed in the paragraph. Replace the fi lters when necessary.
2) CLEANING OF FILTERS AND EXCHANGER
Remove the main unit (1+2+3) from the wall using a fl at-head screwdriver to actuate the hook placed bottom centre of the
unit as shown below.
Once the functioning unit has been unfastened from the wall (4i) extract it with your hands, pulling hard as in the image
below:
33