ELECTRONIC PANEL LRX 2271
Single-phase electronic control unit for the automation of
sliding gates, doors and barriers with incorporated radio
receiver.
Possibility of integrating a radio system with the control unit
operating as a safety device, composed of an RTX 2278
"Base" transceiver (fitted onto the control unit itself) and a
maximum of two battery-operating RTX 2252 "Sensor"
transceivers to connect mechanical and 8.2 kohm-resistive
safety edges, generally positioned on the mobile part of the
gate.
- Mod. LG 2271
- Mod. LRS 2271
- Mod. LRS 2271 SET
- Mod. LRH 2271
I
MPORTANT FOR THE USER
- The device can be used by children over 8 years of
age and persons with reduced physical or psychological
abilities or with little knowledge and experience only if
supervised or educated in its operation and safe use, in
order to also understand the dangers involved in its
use.
- these instructions are also available at the website
www.seav.com
- Do not allow children to play with the device and keep
the radio controls away from their reach.
- Frequently examine the system to detect any signs of
damage. Do not use the device if it is in need of repair
work.
-Always remember to disconnect the power supply
before carrying out any cleaning or maintenance.
- Cleaning and maintenance must not be carried out by
unsupervised children
- ATTENTION: keep this instruction manual safe and
observe the important safety requirements contained
herein. Failure to comply with the requirements may
cause damage and serious accidents.
I
the
MPORTANT FOR
INSTALLER
17) Before automating the gate, check that it is in good
conditions, in compliance with the Machinery Directive
and with EN 12604.
18) Check that the location where the installation is
located
enables
compliance
temperature limits specified for the device.
19) The safety of the final installation and compliance
with all prescribed Standards (EN 12453 - EN 12445)
is the responsibility of the person who assembles the
various parts to construct a total closing.
20) Once installation is finished, it is recommended
that all necessary checks be performed (appropriate
programming of the control panel and correct
installation of safety devices) to ensure that compliant
installation has been performed.
21) The control unit does not have any type of isolating
device for the 230 Vac line. It is therefore the
responsibility of the installer to set up an isolating
device inside the system. It is necessary to install an
omnipolar switch, surge category III. It must be
positioned to provide protection from accidental
closing, pursuant to point 5.2.9 of EN 12453.
GB
: Without radio receiver
: 433.92 Mhz
: 433.92 Mhz "narrow band"
: 868.3 Mhz "narrow band"
with
operating
22) For the power supply cables, use flexible cables in
an insulating sheath in harmonised polychloroprene
(H05RN-F) with a minimum conductor section of 1mm2
23) The various electrical components external to the
control unit must be cabled in accordance with
standard EN 60204-1 as amended, and as set forth in
point 5.2.7 of EN 12453. Power cables may have a
maximum diameter of 14 mm. The fixing of power and
connection cables must be secured through the use of
"optional" cable glands supplied. Pay careful attention
when fastening the cables so that they are anchored in
a stable manner.
Furthermore, care is required when drilling holes in the
outside casing where connecting and power supply
cables will pass, and when assembling the cable
glands, so that everything is installed so as to maintain
the panel's IP protection characteristics.
24) The assembly of a push button panel for manual
control must be completed positioning the push button
panel in such a way that the user is not placed in a
dangerous position.
25) The rear part of the casing is equipped with
fittings for wall mounting (it is possible to drill holes for
installation with plugs, or there are already holes
available for installation with screws). Plan and
implement all necessary measures to achieve an
installation that does not alter the IP protection.
26) The gear motor used to move the gate must
comply with the requirements of point 5.2.7 of EN
12453.
27) The D.S. Power Supply output must be dedicated
to the power supply of the photocells only. It cannot be
used for other applications.
28) With every operation cycle, the control unit
performs
the photocell
protection against the rupture of Category 2 crush-
proof devices, in accordance with point 5.1.1.6. of EN
12453. Accordingly, if the safety devices are not
connected and/or are not working, the control unit is
not enabled for operation.
29) The safety function ensured by the control unit is
active only during closing, therefore, protection on
opening must be ensured in the installation phase with
measures (guards or safety distances) independent of
the control circuit.
30) For proper functioning of the radio receiver, if using
one or more control units, the installation at a minimum
distance of at least 3 metres one from the other is
recommended.
Declaration of Conformity
Electronic Control Unit:
LRX 2271 + RTX 2278
comply with the specifications of the Directives
RED 2014/53/EU, EMC 2014/30/EU, LVD 2014/35/EU.
10
operating
test,
ensuring
rev. 3.0 07/09/2016

Publicidad

loading

Este manual también es adecuado para:

Lg 2271Lrs 2271Lrs 2271 setLrh 2271