MAINTENANCE, SERVICING & WINTERIZING
4 /
Winterizing
Your heat pump is designed to operate in all weather. However, we recommended not leaving it
outside for prolonged periods of time, in particular during winter.
In the off-season, when the ambient temperature is below 10°C, the POOLICAN must be switched
off and winterized to avoid any damage caused by freezing.
To do this :
1.
Switch off the power to the POOLICAN heat pump.
2.
Drain the water from the pool or close the circulation valves. If you intend on keeping the
water in the pool, we recommend covering your pool.
3.
Disconnect the water suction line and return line from the POOLICAN.
4.
Drain the remaining water from the POOLICAN by opening the drain plug.
5.
Screw the drain plug back into the device and conduits, or plug them using a rag into to
prevent foreign objects from entering the device through the pipework.
6.
Store the POOLICAN in a clean and dry place.
When restarting the POOLICAN, your pool water must be clean (no algae or debris, etc.) and, if
necessary, the water must be replaced and the salinity tested and adjusted.