BREAKDOWN AND FAULTS
Code
Error
Reminder to clean the filtration system
CF
Water flow switch protection
d1
Fault in the water inlet temperature
d2
sensor
Fault in the water outlet temperature
d4
sensor
Water temperature protection (Anti-
freeze Level 1)
d6
Antifreeze Level 2
d7
Significant difference between the water
d8
temperature at the inlet and the outlet.
Internal and external communication
E0
failure
Fault in the tube water temperature
E3
sensor
System exception
E4
Fault in the temperature sensor on the
E7
outer ring
Fault in exhaust sensor
E8
Internal error
E9
Failure to communicate with the control
EC
board
Fault in electronic communication system Automatically clears (switch the POOLICAN off and on again)
EE
DC fan malfunction
EF
Gas suction sensor fault
EH
Upper housing protection
EP
Voltage sensor fault
EU
Unable to communicate with the chlori-
F1
nator
Too much salt
F2
Lack of salt
F3
Electrode malfunction (must be manually
F4
cleared)
30 |
EN
Clean or check the filter. RAZ up arrow + filtration
Check that water is properly flowing through the pipes, ensure the
filter is clean, and the inlet/outlet valves are open.
If this does not solve the problem, contact customer support to
reconnect or replace the flow sensor.
Contact customer support to reconnect or replace the sensor
Contact customer support to reconnect or replace the sensor
This protective measure is triggered when the water temperature
is too low and the device in on standby: No intervention is requi-
red; consider winterizing the POOLICAN. Clears by itself once the
temperature returns to normal.
This protective measure is triggered when the water temperature
is too low and the device in on standby: No intervention is requi-
red; consider winterizing the POOLICAN
Check that water is properly flowing through the heat pump,
ensure the filter is clean, and the inlet/outlet valves are open.
Contact customer support to reconnect or replace the sensor.
Automatically clears (switch the POOLICAN off and on again)
Contact customer support to reconnect or replace the sensor
Automatically clears (switch the POOLICAN off and on again)
Contact customer support to reconnect or replace the sensor
Contact customer support to reconnect or replace the sensor
Automatically clears (switch the POOLICAN off and on again)
Automatically clears (switch the POOLICAN off and on again)
Clears after 3 attempts to restart every 10 minutes (if problem
persists, contact customer support)
Contact customer support to reconnect or replace the sensor
Automatically clears (switch the POOLICAN off and on again)
Contact customer support to reconnect or replace the sensor
Automatically clears (switch the POOLICAN off and on again). If the
problem persists, contact customer support to check the connec-
tions of the chlorinator output cables
High salinity/Too much salt added/Drain water (see maintenance).
Disappears once salinity returns to normal.
Low salinity/Not enough salt in water/Add salt (see maintenance).
Disappears once salinity returns to normal.
Contact customer support for cell cleaning