BREAKDOWN AND FAULTS
Code
Error
System detection circuit malfunction
F5
(must be manually cleared)
Abnormal temperature range of the
F6
water in the chlorinator
High pressure protection
H1
Low pressure protection
H2
AC low voltage protection
P1
Overcurrent protection
P2
System protection
P3
Exhaust temperature is too high
P4
Refrigeration fault and undercooling
P5
during self-cleaning
External refrigeration coil is too high
P6
Overheat protection
P7
Outside ambient temperatures is too
P8
high and protection too low
Internal protection
Compressor operation fault
IPM overcurrent
Compressor not responding to inputs
Compressor overcurrent
Input voltage error
IPM current sampling fault
Shut down due to overheating
Logic preload failure
DC bus overvoltage
DC bus undervoltage
P9
AC input undervoltage
AC input overcurrent
Input voltage fault
DSP and PFC communication failure
Temperature sensor malfunction
Communication failure between DSP and
network adapter
Abnormal communication with mother-
board
Shut down due to IPM module overhea-
ting
Faulty compressor model
Automatically clears (switch the POOLICAN off and on again).
Contact customer support if problem persists
Check the water temperature is not below 10°C or above 40°C (if
necessary, winterize the POOLICAN or cool down the water using
the cooling mode)
Clears after 3 attempts to restart every 30 minutes (if problem
persists, contact customer support)
Automatically clears (switch the POOLICAN off and on again)
Automatically clears (switch the POOLICAN off and on again)
Switch the POOLICAN off and on again, if problem persists contact
customer support
Contact customer support to check gas pressure.
Switch the POOLICAN off and on again, if problem persists contact
customer support
Switch the POOLICAN off and on again, if problem persists contact
customer support
Switch the POOLICAN off and on again, if problem persists contact
customer support
Cool down the surrounding environment of the POOLICAN, limit
direct sunlight (put in shade)
Automatically clears (switch the POOLICAN off and on again)
Resolution