5c. Settings
1
2
3
7
8
9
13
14
15
5d. Hydrolysis menu
The hydrolysis has not reached the required production rate.
1
2
3
1
Hydrolysis: Programming of hydrolysis functions.
2
Level: Chlorine production (%) required.
3
Cover: Closed cover safety activation.
Reduction: % of chlorine production when the cover is closed (20% by default).
AquaRite
HC LS
®
Only use spare parts supplied by Hayward brands
4
5
10
11
3
Settings: preferred language.
combination of 5 numbers and the
5
Settings: date and time.
system will memorise them.
7
13
Settings: screen brightness (0-
Cell hours: Information about the
100%), home screen data display,
hours of operation of the cell and the
and calibration of the touchscreen.
number of resets.
Screen timed On/Off programming.
14
System info: Information about the
9
Sound: Programming the sound
software version available on the
transmission system for the following
screen and the Power module.
15
functions: Keyboard (key touch),
Service menu: Menu accessible by
Pop-ups (urgent messages), Alerts
password. Ask your reseller for more
(operational
alarm).
information.
11
Password: Protects access to the
user menu by setting up a password.
To create your password, type in a
4
5
4
Boost (Super Chlorination): Press On.
5
Shock validation: Continuous chlorine production for 24 hours (the production
level must be configured to the maximum). Request for activation with or without
ORP control.
Page 12 on 22
®
5e. Filtration control
The electrolysis and measurements will not activate unless the filtration is running.
6
1
2
12
5
6
1
Filtration modes.
2
Manual: Allows the filtration process to be turned
on and off manually.
3
Filter cleaning: This mode is used to backwash
the filter.
4
Automatic: In this mode, filtration is turned on and
off according to the start and end times. These
time slots must be programmed within a single day
(midnight to midnight).
4
Smart: mode may be activated if and only if
the temperature probe has been activated. This
mode is based on the automatic mode, with its
three filtration intervals, but the filtration times are
adjusted according to the temperature. This is
done by setting two temperature parameters: the
maximum temperature, above which the filtration
times will be determined by the time slots, and
the minimum temperature, below which filtration
will be reduced to five minutes, the minimum
operation period. Between these two temperatures,
the filtration times will be staggered linearly. The
antifreeze mode can be activated to turn the
filtration on if the water temperature falls below
2°C.
3
4
7
5
Heating: mode may be activated if and only if
(minimum two hours and maximum 24 hours). The
the temperature probe and heat pump are both
filtration will operate for at least ten minutes every
activated and configured. This mode acts in the
two hours to check the temperature. The minimum
same way as the automatic mode, but it can also
filtration time selected is divided into twelve
operate via a relay that controls the temperature.
sections that are added to these ten minutes.
The set point temperature is determined in this
Example 1: Over twelve hours, the time is divided
menu and the system operates with a hysteresis
between the twelve times a day when the filtration
of one degree (for example: if the set point
starts up to check the temperature.
temperature is 23°C, the system will start up when
Example 2:
the temperature falls below 22°C and shut down
(12 hours x 60 minutes) / 12 = 60 minutes every
only when it rises above 23°C).
two hours. This is the filtration and heating period
Heating control OFF: The heating operates only
every two hours. If the programmed filtration period
during the configured filtration periods.
ends and the required temperature has not been
Heating control ON: Keeps the filtration on after
reached, the filtration and heating remain on until
the filtration period has expired if the temperature is
the required temperature is reached. To minimize
below the set point temperature. When the setpoint
the number of hours during which filtration operates
temperature is reached, the filtration and heating
each day, this additional time will be deducted from
stop and only resume when the next programming
the next filtration periods occurring during the rest
period begins.
of the day. (See the chart below).
6
Intelligent: mode may be activated if and only if
the temperature probe and heat pump are both
activated and configured. In this mode, the user
has two operating parameters: select the required
water temperature and the minimum filtration time
Intelligent mode operation if the temperature is constant
Intelligent mode operation if the temperature varies
AquaRite
HC LS
Page 13 on 22
®
Only use spare parts supplied by Hayward brands
®
Thermal circuit breaker /
Switch
Contactor
Pump