Installation
Selection of installation equipment
Cut out the work surface according to the sizes shown in the drawing.
•
For the purpose of installation and use, a minimum of 50mm space shall be
•
preserved around the hole.
•
Be sure the thickness of the work surface is at least 30mm. Please select heat-
resistant work surface material to avoid larger deformation caused by the heat
radiation from the hotplate. As shown below:
Warning: The work surface material must use the impregnated wood or other insulation
material.
CI642CBB/1
Under any circumstances, make sure the hob is well ventilated and the air inlet
and outlet are not blocked. Ensure the hob is in good work state. As shown below
Note: The safety distance between the hotplate and the cupboard above the hotplate
should be at least 760mm.
L(mm)
W(mm)
590
520
H(mm)
D(mm)
58
54
23
A(mm)
B(mm)
560
490
X(mm)
50 mini