Descargar Imprimir esta página

HomeMatic IP HmIP-SK9-2 Manual De Instalacion Y Uso página 31

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 62
Start-up
6.2.4 Danfoss RA adapter
The provided adapter is required to at-
tach to Danfoss RA valves. If necessary,
use a screwdriver to slightly bend open
the adapter.
The Danfoss valve bodies have elon-
gated notches around their circumfe-
rence, which ensure that the adapter is
properly seated when it snaps on.
Figure 7
During installation, please ensure
that the pins inside the adapter
are lined up with the notches on
the valve. Ensure that a suitable
adapter for the valve is properly
clipped on.
Please ensure that you do not
trap your fingers between the two
halves of the adapter!
After clipping onto the valve body, ple-
ase attach the adapter using the provi-
ded screw and nut.
6.3
Adaption run
Once the batteries have been
inserted, the motor reserves. Me-
anwhile, "InS" and the activity
symbol ( ) are displayed.
Figure 8
Once the batteries have been
inserted, the motor reserves. Me-
anwhile, "InS" and the activity
symbol ( ) are displayed.
After the radiator thermostat has been
mounted successfully, an adaption run
(AdA) has to be performed in order to
adapt the device to the valve:
As soon as "AdA" is displayed, press
the menu/boost button (G) to start the
adaption run.
It is now that the radiator thermostat
performs an adapting run. "AdA" and
the activity symbol ( ) are displayed.
Wait until the adaption run is com-
pleted. Afterwards, the display returns
back to normal.
2
Figure 9
1
31

Publicidad

loading