These instructions apply to all T5S AUTO drive, the different versions of which are available in the current catalogue.
Field of application: T5S AUTO drive are designed to drive all types of roller shutters equipped with stop blocks and rigid links. The installer,
who must be a motorisation and home automation professional, must ensure that the drive product is installed in accordance with the
standards in force in the country in which it is installed such as EN 13659 relating to roller shutters.
Liability: Before installing and using the drive, please read operating and installation guide carefully. In addition to following the
instructions given in this guide, the instructions detailed in the attached Safety instructions document must also be observed. The drive
must be installed by a drive and home automation professional, according to instructions from SIMU and the regulations applicable in the
country in which it is commissioned. It is prohibited to use the drive outside the fields of application described above. Such use, and any
failure to comply with the instructions given in this guide and in the attached Safety instructions document, absolves SIMU of any liability
and invalidates the warranty. The installer must inform its customers of the operating and maintenance conditions for the drive and must
provide them with the instructions for use and maintenance, and the attached Safety instructions document, after installing the. Any After-
Sales Service operation on the drive must be performed by a drive and home automation professional. If in doubt when installing the drive,
or to obtain additional information, contact a SIMU adviser or go to the website www.simu.com.
1
INSTALLATION
Instructions which must be followed by the drive and home automation professional installing the drive:
- Methods of wiring are given by national standards or IEC60364 standard.
- If the motor is used outdoors and if the power supply cable is of the H05VV-F type, then run the cable in a UV-resistant conduit, e.g.
trunking. Cables which pass through a metal wall must be protected and isolated using a sheath or sleeve.
- The cable for the motor can be removed. If it is damaged, replace by the same. The cable may only be connected to the motor by qualified
personnel. The connector is to be assembled without damaging the contacts. The continuity of the earth connection must be ensured.
Recommendations: The motor torque must be selected according to the shutter's characteristics. Do not oversize the operator. To receive
information regarding the compatibility of the motor and the roller shutter or/and accessories, contact the roller shutter manufacturer or
SIMU.
Drilling of the tube:
Mounting:
6
2
WIRING
- Attach cables to prevent any contact with moving parts.
- The motor can not be use with control devices such as: emergency power supply (ie: regulated power supply, power generating unit,
triac, ex, ....). Use only mechanical or electromechanical switches (e.g. relays) to control a motor. The relay contacts must not be
bypassed by capacitors. The motors should not be controlled by a relay or triac with static capacitor.
- Set time between UP and DOWN order to 500 ms minimum.
- The length of the cable between the electrical switch and the motor must not exceed 100 m.
48
Ø62
21
4
6/17 • 10/17
T5S AUTO
15/17
230V~50Hz
20/17 • 25/17 • 35/17
5
1
L1
IP44
L2
Ø4,8 x 10
STEEL
4
Ø5 x 10
3
2
5166925A
EN- ORIGINAL INSTRUCTIONS
i
A
4xØB / 90
A
ØB
L1
(mm)
(mm)
(mm)
483
496
503
5
516
670
657
V.A.S
EASYLINK
OCTOEASY
MANDATORY
-20°C / +60°C
47 min.
L2
(mm)
517
537
691
EN