N
230V~50Hz
L
PE
Blue
Brown
T5S AUTO : 6/17 - 10/17 - 15/17
T5S AUTO ≤ 15 Nm motors do not allow parallel
wiring of several motors on one unipolar switch.
3
POWER UP OF THE OPERATOR
>>
After the first two consecutive and complete opening and closing of the shutter:
- The motor memorizes automatically the end limit (up and down) positions.
- The «stop on obstacle» function is activated.
It is advised to carry out these two opening / closing cycles as soon as the product is installed.
4
CANCELLING THE AUTOMATIC SETTINGS
In the case of a new installation with this operator, it is advised to reset the motor according to the following procedure:
- Press 3 consecutive times, for 1 s. each time, on the ▲ key. The motor runs briefly at each press.
- Press 3 consecutive times on the ▼ key. The first two press for 1s. (the motor runs briefly at each press) and the third press
for 2 s. The motor runs twice in the same direction.
>>
>>
1 s
1 s
5
OPERATION AND MAINTENANCE
- This drive is maintenance-free.
- Press the ▲ button on the control point to raise the motorised product.
- Press the ▼ button on the control point to lower the motorised product.
Tips and recommendations for use:
Observations
The motorised product does not operate.
If the motorised product still does not work, contact a drive and home automation professional.
We care about our environment. Do not dispose of the appliance with usual household waste. Give it to an approved
collection point for recycling.
Somfy limited, Yeadon LS19 7ZA UK hereby declares that the drive covered by these instructions when marked for input voltage 230V~50Hz and used
as intended according to these instructions, is in compliance with UK legislation of Machinery safety regulations S.I.2008 N°1597. The full text of the
UKCA declaration of conformity is available at www.somfy.co.uk. Steven MONTGOMERY, Managing Director Somfy Ltd UK & Ireland, Yeadon, 06/2023.
SIMU SAS, 70100 ARC-LES-GRAY, France, as manufacturer hereby declares that the drive covered by these instructions when
marked for input voltage 230V~50Hz and used as intended according to these instructions, is in compliance with the essential
requirements of the applicable European Directives and in particular of the Machinery Directive 2006/42/EC and EMC Directive
2014/30/EU. The full text of the EU declaration of conformity is available at www.simu.com.
Bruno STRAGLIATI, Chief Executive, ARC-LES-GRAY, 06/2023.
EN
2/2
Black
Green/Yellow
>>
>>
1 s
The overheating protection on the drive has been
T5S AUTO
T5S AUTO : 20/17 - 25/17 - 35/17
Possibility of wiring 3 motors T5S AUTO ≥ 20 Nm
max. in parallel on one unipolar switch.
>>
>>
>>
>>
1 s
1 s
Possibles causes
activated.
OK
>>
ON
>>
ON
>>
Wait until the motor cools down.
OFF
>>
>>
2 s
Solutions