SAFETY INFORMATION
tough rubbersheathed flexible cable (in accordance with ICE
245 or the equivalent should be used. When using extension
lines or mobile distribution networks the total length of lines
for a cross section of 1.5 mm
cross section of 2.5 mm
2
Electrical equipment (including lines and plug connections)
should not be defective.
There is permanent conductor between the generator
(stator winding) and the frame. The generator (stator
winding) is isolated from the frame and from the ac
receptacle ground pin. Electrical devices that require a
grounded receptacle pin connection will not function if
the receptacle ground pin is not functional.
WARNING
Don't add fuel near
the flammable thing
or cigarette.
WARNING
Keep children and
pets away from the area
of operation. Do not place
flammable objects close to
the outlet valve when
generator operation.
Keep it least 1 m away
from inflammables.
WARNING
The generating set
must not be connected to
other power source, such
as the power company
supply main. Protection
against electrical shock
depends on circuit breaker
spacially matched to the
generating set. Due to high
machanical stresses only,
should not exceed 60 m; for a
2
this should not exceed 100 m.
WARNING
It must realize safe
grounding.
NOTICE
Use the ground wire with
enough electric flux.
Ground wire diameter:
0.12 mm/A
EX: 10A-1.2 mm
WARNING
The generator surface
has high temperature, avoid
scalding. Pay attention to
the warnings on the
generating set.
Connection to home power supply
If the generator is to be connected to a home power supply
as standby, connection shall be performed by a professional
electrician or by another person with proficient electrical skill.
When the loads are connected to the generator, please
carefully check whether electrical connections are safe and
reliable. Any improper connection may cause damage to
the generator, or cause a fire.
Right
If the generator is to be connected to a home power supply
as a standby, connection shall be performed by a professional
electrician or by another person with proficient electrical skill.
When the loads are connected to the generator, please
carefully check whether electrical connections are safe and
reliable. Any improper connection may cause or damage to
the generator.
Others
Make sure Inverter ducted fan, muffler louver and the inverter
bottom side cooling well and without chips, mud and water
come in. it may damage the generator, inverter or alternator
if the cooling vent blocked.
Do not mix the generator with other stuff if moving, storing
or running the unit, It may cause generator damage or bring
property safety issue when the inverter in leakage.
There is the warning label on the machine to remind you of
the safety regulations.
2
Wrong
Right