PRE-OPERATION
Oil level
OPERATION
Operation
NOTICE
Never operate the engine in a closed area or
it may cause unconsciousness and death
within a short time. Operate the engine in
a well ventilated area. The generator has been
shipped without engine oil. Do not start the
engine till fill with the sufficient engine oil.
Tip:
• The generator can be used with the rated output load
at standard atmospheric conditions.
• "Standard atmospheric conditions"; Ambient
temperature 25c.
• Barometric pressure lOOkPa; Relative humidity 30%
• The output of the generator varies due to change
temperature, altitude (lower air pressure at higher
altitude) and humidity.
• The output of the generator is reduced when the
temperature, the humidity and the altitude are higher
than standard atmospheric conditions.
• Additionally, the load must be reduced when using in
confined areas, as generator cooling is affected.
Starting the engine
Recommended engine oil:
SAE 10W -30
Recommended engine oil
grade: API Service SE type
or higher
Engine oil quantity: 0.6 L
Before starting the engine,
do not connect any electric
devices.
Turn the ESC switch to
u
"OFF"
.
Turn the 3 in 1 switch to
v
"CHOCK"
a. Ignition circuit is
switched on.
b. Fuel is swiched on.
c. Chock is switched off.
TIP: The choke is not
required to start a warm
engine. Push the choke
knob in to the position
"ON".
TIP:
When starting the engine, with the ESC "ON" and there is
no load on the generator: IN ambient temperature below
0° C (32° F), the engine will run at the rated (3100 r/min) for
5 minutes to warm up the engine. In ambient temperature
below 5° C (41° F), the engine will run at the rated r/min
(3100 r/min) for 3 minutes to warm up the engine.
The ESC unit operates normally after the above time period,
while the ESC is "ON".
6
Electric start
Turn the engine switch on
the control panel to ON.
And press it to START or
turn key right if it's electrical
start state, then generator
unit can be started. In order
to extend the service life of
the storage battery, do not
press on the switch for more
than 3 seconds and the
interval between two
pressings should be longer
than 10 seconds.
Recoil start
Grasp the carrying handle
firmly to prevent the
generator from falling over
when pulling the recoil
starter.
After the engine starts, warm
up the engine until the
engine does not stop when
the choke knob is returned
w.
to the "ON" position