CONTROL FUNCTION
Frequency selection (FS) switch only for 100V product
Frequency selection
NOTICE
Frequency switch can change frequency only
when the generator setting stops.
The generator setting output frequency can't
change if it operates.
DC protector
u
"ON" Direct current is output.
v
"OFF" Direct current is not output.
NOTICE
Reduce the load of the connected electric
device below the specified rated output of
the generator if the DC protector turns off.
If the DC protector turns off again, stop
using the device immediately and consult a
franchised dealer.
PRE-OPERATION
NOTICE
Pre-operation checks should be made each
time operation.
WARNING
The engine and muffler will be very hot
after the engine has been run. Avoid touching the
engine and muffler while they are still hot with any
part of your body or clothing during inspection or
repair.
Fuel
WARNING
• Fuel is highly flammable and poisonous.
Check "SAFETY INFORMATION" (See page 1-3)
carefully before filling.
• Do not overfill the fuel tank, otherwise it may overflow
when the fuel warms up and expands. After fill the fuel,
make sure the fuel tank cap is tightened securely.
• Immediately wipe off spilled fuel with a clean.
• Use only unleaded gasoline. The use of leaded gasoline
will cause severe damage to internal engine parts.
u
50Hz
v
60Hz
If you need change the
machine output frequency,
please stop the generating
set firstly, then adjust
the position of frequency
switch by screwdriver.
Then restart it.
The DC protector turns to
"OFF" automatically when
electric device being
connected to the generator
is operating and current
above the rated flows.
To use this equipment again,
turn on DC protector by
pressing its button to "ON"
Ground (earth) terminal
Parallel operation outlets
The handling, operation procedure and the notes on usage
are described in the PARALLEL RUNNING KIT OWNER'S
MANUAL included in the Parallel.
Brake
Make sure enough gasoline in fuel tank.
Recommended fuel: Unleaded gasoline
Fuel tank capacity: Total: 10.0L
u
Fuel level gauge
Engine oil
5
Ground terminal
u
connects
the earth line for prevention
of electric shock. When the
electric device is earthed,
always the generator must
be earthed.
u
This is the terminal
for
connecting special cables
for parallel running of two
generator. The parallel
running requires two
generator and the special
cables. (The rated output in
parallel running is 5.6 Kva
and the rated current is
60A/100V;50A/120V;
26A/230V.)
During the operation and
idle period of machine,
brake timely and switch to
"STOP".
In case of the machine
required to be move, switch
the brake to "RUN".
The generator has been
shipped without engine oil.
Do not start the engine till fill
with the sufficient engine oil.
Do not tilt the generator
when adding engine. This
could result in overfilling
and damage to the engine.