CONNECT HOSES AND PRIME PUMP
1. Hose washer with screen (A) is already attached into
end of brass hose coupler.
NOTE: Conical screen in washer (A) should protrude out of
coupler and into flow from inlet hose.
IMPORTANT: If washer is to be connected to a well water
system, use 851-0207 water inlet filter (A).
This will increase sand filtering capability
and avoid damage to the pump.
2. Install inlet water hose (A) and hand tighten. Install high
pressure discharge hose (B) with quick connect.
Operator's Manual
Preparing the Washer
A
A
B
A
17