SPECIFICATIONS
ITEM
Water Pump ................................................................... 1.5 GPM (6.62 L/min)
Electric Motor ................................................................. 120 volts, 15 amps, single phase, 60 Hertz, 1.5 HP,
Electrical Power Requirements ...................................... Voltage at power supply with washer running must be
Water Supply Requirements .......................................... Inlet water supply pressure - 20 PSI (1.4 Bar) minimum
Discharge Hose ............................................................. 25 ft. x 3/8 in. (7 m x 6.4 mm) minimum 3000 PSI (207 Bar)
Power Cord .................................................................... 35 ft. (10.7 m), 14 gauge, 3 conductor, water resistant,
Nozzle Wand .................................................................. Nozzle size -- .037 in. (0.95 mm)
RECORD SERIAL NUMBER
Write you model number, machine serial number (see
serial number tag (A) in illustration) and date of purchase
in the spaces provided below. Your dealer needs this
information when ordering parts.
Model No. ______________________________________________
Machine Serial No. _______________________________________
Date of Purchase ________________________________________
(To be filled in by purchaser)
Operator's Manual
Specifications
SPECIFICATION
1400 PSI (96.5 Bar) (9652 kPa) at pump
1725 RPM, thermal-protected manual reset.
greater than 108 VAC.
Inlet water supply volume - 3 GPM (11.4 L/m) minimum
Inlet water supply hose - 5/8 in. (15.9 mm) minimum I.D.
50 ft. (15.2 m) maximum length
Cold water only
working pressure, acid and oil resistant
with ground fault circuit interrupter (GFCI).
Color of dot - Pink
A
33