Preparation
Electrical Connection
To properly install your oven, you must determine the type of electrical connection
you will be using and follow the instructions provided in this manual.
Oven must be connected to the proper electrical voltage and frequency as
specified on the model/serial/rating plate. The model/serial/rating plate is
located on the bottom left side of the trim. See the following illustrations.
Single Oven
A. Model/serial/rating plate
A circuit breaker is recommended.
Use the chart below to determine the minimum recommended dedicated
circuit protection.
KW Rating (240 V)
≤4.8 KW
4.9 KW - 7.5 KW
7.3 KW - 9.6 KW
9.7 KW - 12.0 KW
Connect directly to the circuit breaker box (or fused disconnect) through
flexible, armored or nonmetallic sheathed, copper cable (with grounding wire).
See "Electrical Connection" section.
10 English
Install_DOB30x977xx_DG68-01308A-01_EN+MES+CFR.indb 10
Install_DOB30x977xx_DG68-01308A-01_EN+MES+CFR.indb 10
A
Double Oven
A. Model/serial/rating plate
Recommended Circuit
KW Rating (208 V)
Size (Dedicated)
≤4.1 KW
20 Amp
4.3 KW - 6.2 KW
30 Amp
6.3 KW - 8.3 KW
40 Amp
8.4 KW - 10.4 KW
50 Amp
Flexible conduit from the oven should be connected directly to the junction
box.
Fuse both sides of the line.
Do not cut the conduit. The length of conduit provided is for serviceability of
the oven.
A UL listed or CSA approved conduit connector must be provided.
If the house has aluminum wiring, follow the procedure below:
1.
Connect a section of solid copper wire to the ends of the flexible conduit
leads.
2.
Connect the aluminum wiring to the added section of copper wire using
special connectors and/or tools designed and UL listed for joining copper
to aluminum.
Follow the electrical connector manufacturer's recommended procedure.
Aluminum/copper connection must conform with local codes and industry
accepted wiring practices.
A
For power requirements for models DOB30*977S*,DOB30*977D* refer to the
following table.
Model
DOB30*977S*
DOB30*977D*
240 VAC
208 VAC
Power
Circuit Size
Power
5.6 kW
30 Amp
4.2 kW
11.2 kW
50 Amp
8.4 kW
Circuit Size
30 Amp
50 Amp