GB
Fold out pages:
Application
Prod. No. 36 096:
Single-hole mixer suitable for:
• Direct connection to cold water supply
• Connection to outlet of upstream mixed water supply
Prod. No. 36 095 and 36 097:
Can be used in conjunction with:
• Pressurised storage heaters
• Thermally-controlled instantaneous heaters,
• Hydraulically-controlled instantaneous heaters
Operation with unpressurised storage heaters
(displacement water heaters) is not possible.
Safety notes
• Installation is only possible in frost-free rooms.
• The transformer is only suitable for indoor use.
• In the case of damage to the external transformer
connection cable, this must be replaced by the manufacturer
or his customer service department or an equally qualified
person, in order to prevent a hazard.
• For cleaning purposes, the transformer plug must not be
directly or indirectly sprayed with water.
• The voltage supply must be separately switchable.
• Use only genuine replacement parts and accessories. The
use of other parts will result in voiding of the warranty and
the CE identification.
Technical data
• Flow pressure
min. 0.5 bar - recommended 1 - 5 bar
• Operating pressure
• Test pressure
If static pressure exceeds 5 bar,
a pressure-reducing valve must be fitted.
Avoid major pressure differences between
hot and cold water supply.
• Flow rate at 3 bar flow pressure:
• Temperature:
Hot water supply:
Recommended (energy saving):
• Supply voltage (transformer 230 V AC/12 V AC):
• Power consumption:
• Automatic safety shut-off
(factory setting):
• Run-on time (factory setting):
• Reception range with Kodak Gray Card,
grey side, 8 x 10", landscape, 5cm below
the spout (factory setting):
• Type of protection: - Fitting
- Transformer
• Water connection
The test for electromagnetic compatibility (interference
emission test) was performed at the rated voltage and rated
current.
Special accessory
• Infrared remote control (Prod. no. 36 206) for changing the
factory settings and selecting special functions.
3
Approval and conformity
This product conforms to the requirements of the
relevant EU guidelines.
The conformity declarations can be obtained from the following
address:
GROHE Deutschland Vertriebs GmbH
Zur Porta 9
D-32457 Porta Westfalica
Installation
Flush pipes thoroughly before and after installation
(observe EN 806).
Fitting
Refer to the dimensional drawings on fold-out page I.
Lift rod (A) must be inserted into the mixer body during
installation, see fold-out page II, Fig. [1].
Fasten fitting to wash basin, see Figs. [1] to [3].
Connection
The cold water supply must be connected on the right, hot
water supply on the left.
In order to ensure permanent, trouble-free operation, fitting of
the enclosed adapter is mandatory.
Insert filter (B) and screw adapter (C) together with seal (C1)
onto the service valve, see Fig. [4].
Open hot and cold water supply and check connections
for watertightness.
max. 10 bar
Connecting the voltage supply
16 bar
Connect control electronics with plug-in connector (D) to
transformer (E), see Fig. [5].
Connect voltage supply via transformer (E).
Setting the temperature limiter
approx. 6 l/min
Prod. No. 36 095 and 36 097:
max. 70 °C
1. Remove screw (F), see Fig. [6].
60 °C
2. Turn mixer lever (G) clockwise until the desired maximum
230 V
temperature is reached.
3.2 VA
3. Detach mixer lever (G), see Fig. [7].
4. Detach stop ring (I) and reattach with notch (I1) pointing
60 s
vertically upwards.
1 s
5. Turn mixer spindle (H) anti-clockwise to the stop.
6. Attach mixer lever (G) in horizontal position and fasten with
screw (F).
approx. 15cm
IP 59 K
IP 44
Operation
cold - right
The infrared electronics emit invisible, pulsed light.
hot - left
The infrared-electronics are adjusted so that water flow is
initiated when the hands approach the vicinity of the spout.
When the hands are withdrawn from the vicinity of the spout,
water flow is stopped after 1 s (factory setting).
The range of the sensor system is dependent upon the
reflective properties of the detected object.
Automatic safety shut-off
After 60 s (factory setting) of continuous detection of an object,
the infrared electronics automatically stop the water flow.