Descargar Imprimir esta página
Federal Signal Vitalite 121SLED Manual Del Usuario
Federal Signal Vitalite 121SLED Manual Del Usuario

Federal Signal Vitalite 121SLED Manual Del Usuario

Luz giratoria led

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

Model 121SLED
Vitalite
LED Rotating Light
®
25500629 Rev A2 1123
Limited Warranty: This product's limited warranty can be
found at www.fedsig.com/SSG-Warranty
SAFETY MESSAGES TO INSTALLERS AND USERS
Products should be installed by a licensed electrician and
follow all safety instructions. Failure to do so may result
in property damage, serious injury, or death.
Read and understand instructions before installing
or operating equipment.
To avoid electrical shock hazards, do not connect
wires when power is applied.
To be an effective warning device, this product
produces bright light that could be hazardous to
eyesight. The possibility exists that rapid flashing
lights could induce photosensitive epilepsy. Do not
stare directly at the light.
OVERVIEW - The model 121SLED rotating LED warning
light is designed for mounting on a flat (horizontal or
vertical) surface or on a 1/2" NPT threaded pipe. Units are
available in 120VAC 50/60 Hz.
Certifications and Ratings
UL and cUL Listed
Type 4X, IP66 enclosure. Indoor/Outdoor Use
IP69K Compliant
Model 121SLED is NSF Certified (dome-up) for
Splash Zones and Non-food Zones to NSF/ANSI 2:
Food Equipment
Electrical ratings: 120VAC 50/60Hz, 0.075A
Certified operating temperature: -40°F to 150°F
(-40°C to 66°C)
Unpacking the Device:
examine it for damage and verify the parts. If a part is
missing or damaged, do not attempt to install it; contact
Federal Signal Customer Support.
Installation
Mounting the Device
The unit comes standard to mount on a flat (horizontal
or vertical) surface or a 1/2" NPT pipe. Wall or corner
mounting accessories are sold separately.
Pipe Mounting: On a 1/2" NPT Pipe, feed the wires
through the pipe and turn clockwise to tighten. The
recommended tightening torque is 5-ft-lb (6.8 N-m).
After unpacking the device,
:
Screw
in base
Surface/Panel Mounting: Using the provided gasket as a
template, mark three mounting holes and a center hole
for wiring. Drill or punch 3/16" (4.8 mm) diameter holes
for mounting and a 1" (25.4 mm) hole for wiring. Set the
base on the gasket, feed the wires through the center, and
attach the unit to the mounting surface using the provided
#8 tapping screws from the underside.
Wall/Corner Mounting: Wall (Model LSWB) and corner
(Model LCMB2) brackets are sold separately. Mounting
bracket accessories are not NSF Certified.
NOTE: LWMB2 and LCMB2 are Type 3R rated. If installing
in combination with a 4X device, the unit is Type 3R rated.
When Type 4X is required, pair with Model LSWB.
Figure 2 Wall/Corner Mounting
WARNING -SHOCK HAZARD: To avoid electrical shock,
do not connect wires when circuits are energized. Use
18 AWG field wiring or larger.
120VAC 50/60Hz Models: Connect the line (L or L1)
power source lead to the black wire and connect the
neutral (N or L2) power source lead to the white wire.
Connect the ground to the green/yellow wire if required.
Figure 1 Pipe Mounting
Elliptical Dome
(12" Curvature
Radius)
LED Lamp
1/2" NPT
Pipe Mount
5.12"/ 130 mm

Publicidad

loading

Resumen de contenidos para Federal Signal Vitalite 121SLED

  • Página 1 After unpacking the device, examine it for damage and verify the parts. If a part is missing or damaged, do not attempt to install it; contact Federal Signal Customer Support. WARNING -SHOCK HAZARD: To avoid electrical shock, Installation do not connect wires when circuits are energized. Use 18 AWG field wiring or larger.
  • Página 2 Remove the dome and ensure that the gasket between the dome and base is secured. 2645 Federal Signal Drive, University Park, Illinois 60484 Additional translations available at signaling.fedsig.com Traducciones adicionales disponibles en signaling.fedsig.com Customer Support 1-800-344-4634+1-708-534-4756, iordersup@fedsig.com Technical Support 1-800-755-7621+1-708-587-3587, signalsupport@fedsig.com...
  • Página 3 Modelo 121SLED Luz giratoria LED Vitalite ® 25500629 SP Rev A2 1123 Garantía limitada: la garantía limitada de este producto se Instalación puede encontrar en www.fedsig.com/SSG-Warranty Montaje del dispositivo La unidad viene estándar para montarse sobre una Mensajes de seguridad para instaladores y usuarios superficie plana (horizontal o vertical) o sobre un tubo : los productos deben ser instalados por un electricista NPT de 1/2”.
  • Página 4 Entregue una copia de devolución. Comuníquese con su distribuidor autorizado estas instrucciones a todo el personal de operación. o con el servicio de Atención al Cliente de Federal Signal. Los productos defectuosos bajo garantía se repararán o Cambio de la lámpara LED reemplazarán a criterio de Federal Signal.
  • Página 5 Figure 2 Montage mural/en coin Déballage de l’appareil : après avoir déballé l’appareil, examinez-le pour déceler tout dommage et vérifiez les pièces. Si une pièce est manquante ou endommagée, n’essayez pas de l’installer ; contactez le service client de Federal Signal.
  • Página 6 électriques, débranchez l’alimentation et laissez la Retours de produits : Les retours requièrent l’autorisation lampe refroidir. de Federal Signal. Contactez votre distributeur agréé pour obtenir plus d’informations concernant notre politique de Remplacement de la lampe DEL : retour ou pour demander le retour d’un produit.