12.5) TRANSMITTERS REMOTE LEARNING
If an already memorised transmitter is available in the receiver it is possible to carry out remote radio learning (without needing to ac-
cess the control unit).
IMPORTANT: the procedure must be carried out with barrier open.The logic REM must be ON.
Proceed as follows:
1 Press the hidden key of the transmitter which is already memorised.
2 Press, within 5s, the key of the corresponding transmitter which is already memorised to associate to the new transmitter. The flash-
ing light will turn on.
3 Press within 10s the hidden key of the new transmitter.
4 Press, within 5s, the key of the new transmitter to associate to the channel chosen at point 2. The flashing light will turn off.
5 The receiver memorised the new transmitter and immediately exits from programming.
12.6) FUSES
F3 CP.EVA2: T1A - Fuse for the protection of the accessories power supply
F1 SA.24V:
T4A - Fuse for general protection
12.7) BACK UP BATTERIES
The control unit CP.EVA2 includes the power pack SA.24V predisposed for the connection of two batteries by 12Vdc 2,1Ah DA.BT2
(optional) which guarantee the regular functioning of the automation in case of temporary power failure.
When the barrier is working with mains voltage the power pack SA.24V charges the batteries (Fig. 15).
The maximum charging current is 1A, the average charging current is 300 mA.
12.8) DIAGNOSTICS
SW Open
SW Close
P.P.
OPEN
PHOT
STOP
12.9) ERROR MESSAGES
Some messages that are displayed in case of function anomalies are listed as follows:
Generic error
Err
Motor error
Err1
Photocells error
Err2
Absolute encoder error
err3
Amperometric sensor intervention
AMP
Thermal sensor intervention
THRM
Overload
OVLD
Encoder
Enc
28
LED 1 : Presence of mains voltage
LED 2 : Control unit CP.EVA2 correctly powered
To each input is associated a line of the LCD screen which in case of activation it turns
CLOSE
on according to the following diagram.
The N.C. inputs are represented by vertical lines.
The N.O. inputs are represented by horizontal lines.
The flashing mode of the lines SW Open (when the barrier is open) and SW Close (when
the barrier is close) indicates the type of limit switch used.
2 flashes and pause: Presence of mechanical stops, no encoder, no electromechanical
limit switches
1 flash and pause: Absolute encoder version (standard)
No flashing (always on) = Electromechanical limit switches
Error inserting password or memorizing transmitter..
Verify the motor wirings, faulty motor or not connected, problem on the control unit.
Verify connections, photocells alignment and presence of obstacles.
Verify encoder connections, verify the good functioning of the Encoder.
Verify the presence of obstacles or friction points.
Overheating due to a too intensive use, wait the restoring.
Exceeding of the maximum power. Verify the motor and presence of friction points..
Encoder threshold intervention.