Descargar Imprimir esta página

Parkside PLDM A1 Instrucciones De Utilización Y De Seguridad página 54

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 206
D
Object
2 . After the product is calibrated in NFe or Fe test mode,
the product saves the resulting calibration data in this test
mode automatically . The calibration data will not be lost
even when the product switches off or when you replace
the battery .
3 . But whenever you calibrate the product again in the same
test mode, the already existing calibration data saved in this
test mode will be overwritten by the new calibration data .
Only the lastest calibration data of all calibration data
obtained in NFe test mode can be retained in NFe test
mode . Only the lastest calibration data of all calibration
data obtained in Fe test mode can be retained in Fe test
mode .
Calibration procedure
1 . Switch off the product .
2 . Press and hold the UNIT button 
3 . Press and release the TEST button 
54 GB/IE
Coating(s)
Substrate
.
4 ]
[
.
3 ]
[

Publicidad

loading