Troubleshoot common problems
Identify when to install a new cartridge
The best indication of when to install a new cartridge is when the cut quality is no longer
satisfactory.
The following signs can be indications that a cartridge is near or at end-of-life:
Examine the nozzle hole. A
nozzle hole in good condition
is circular. If the nozzle hole
is not circular, replace the
cartridge.
As a cartridge wears,
unwanted material can
collect inside the cartridge
and cause faults to occur. In
some conditions, you can
remove this material by
carefully shaking the
cartridge.
Examine the crown
is the square copper piece inside
of the cartridge. Push down on
the crown and then release it.
A crown in good condition
goes back to its start
position. If the crown stays in
the down position, carefully
shake the cartridge. If the
crown continues to stay in
the down position, replace
the cartridge.