Door Refrgera o
2. Disconnect
2 connectors
( 3 ) at each
side of the top cap and one connector
( 4 ) on the left side door. Remove the
water line ( 5 ) while pressing the dark
gray color part ( 6 ) of the water line
coupler.
CAUTION
If a red clip is on the coupler, it must
be removed before removing the
tube.
3. Remove the 3 hex head bolts ( 7 ) attached
to the
upper left and right door hinges with a socket wrench
(7/16"). Remove the ground screw ( 8 ) attached
to
the upper left and right door hinges with a philips
screwdriver(+).
Remove the upper left and right door hinges ( 9 ).
@
@
Socket wrench
4. Lift the door straight
up to remove.
5. Remove the screw ( 10 ) attached
to the lower left
and right door hinges with a philips screwdriver(+).
Remove the 2 hex head bolts ( 11 ) attached
to the
lower left and right door hinges with an allen wrench
(3/16").
Remove the lower left and right door hinges ( 12 ).
10 Setti_g up