3.5.3
Functions of LEDs A and B
Status
LED A
D650 ready for oper-
Does not illumi-
ation
nate
Data communication
Flashes green
with the controller
(irregular)
Firmware update
Does not illumi-
in operation
nate
LED A
Function
Does not illumi-
No data communi-
nate
cation with the con-
troller
Flashes green
Data communication
(irregular)
with the controller
Illuminated green
Fault in hardware/
Firmware
Illuminated red
Power supply
> 35 Volt.
LED B
Function
Does not illumi-
Voltage not present
nate
Flashes green
D650 ready for op-
(1 second inter-
eration
val)
Illuminated green
Fault in hardware/
Firmware
Flashes yellow
Overvoltage on
(1 second inter-
diagnostic cable
val)
Illuminated yellow Fault in hardware/
Firmware
Flashes red
Firmware update
(irregular)
in operation
Illuminated red
Fault in firmware-
update
Unplug the USB connection and power supply and connect them
*)
again. If the error still exists, contact customer service.
Bosch Automotive Service Solutions S.r.l.
3.6
The D650 can be connected to the D750 via Bluetooth
LED B
or the USB interface.
Flashes green
(1 second interval)
Flashes green
(1 second interval)
Flashes red
(irregular)
Measures
Check connection
with the controller
None
*)
Check voltage in ve-
hicle
Measures
Check power
supply
None
*)
*)
*)
None
Fig. 6:
Repeat firmware
1 OBD interface in motor vehicle
update
2 OBD connection cable
3 D750
4 D650
5 Power supply unit
6 USB connecting cable
7 Connection cable for cigarette lighter socket
Product description | D750 | 23
Connection diagram
1
9
7
2
10
3
11
12
4
13
5
14
6
15
7
16
8
6
D650 connection diagram
1 689 989 216
en
1
2
3
4
5
|
2015-07-01