en
24 | D750 | Initial commissioning
3.6.1
Notes on control unit diagnosis
The D650 is supplied with voltage either via the power
supply unit provided or the OBD interface in the vehicle.
!
If a test step involves starting the engine, the battery
voltage may drop to such an extent that supply via
the vehicle is no longer guaranteed. In such cases
it may be necessary to run the D650 by way of the
power supply unit.
i
On some vehicles, the ignition must be switched on
for power to be supplied via the OBD interface.
Connection to the diagnostic interface in the vehicle is
done using the OBD connection cable (fig. 6, item. 2).
!
Make sure the OBD connection cable is properly
connected to the D650. Incorrect connection could
cause the pins of the plug to bend or break off. Only
use the OBD connection cable contained in the
scope of delivery of the D750.
i
Notes on control unit diagnosis can be found in the
online help for the HUB software (
3.6.2
Firmware update
After an update of HUB, the firmware of the D650 is
updated automatically when the control unit diagnosis
is started.
To update the firmware, supply the D650 using the
provided power supply unit and connect to D750 using
the USB connecting cable. Do not interrupt the USB
connection during the firmware update. The firmware
update can also be done using DDC (Diagnostic Device
Configuration) (see online help on DDC).
!
For the D650, firmware updates must always be
performed using the USB connecting cable (not by
way of Bluetooth).
|
1 689 989 216
2015-07-01
4.
¶
Remove the D750, the D650, the storage battery and
the power supply unit with power supply cable from
the case.
4.1
¶
Insert the storage battery in the storage-battery
compartment and secure using the two screws on
the storage battery (see fig. 3, item 3).
i
It is advisable to charge the storage battery for at least
three hours before running the D750 off the battery.
4.2
Prior to the initial commissioning, make sure the mains
voltage coincides with the voltage specified on the pow-
er supply unit (use the power supply cable provided).
4.3
i
If the storage battery in the D750 has not been
).
charged, supply the D750 with voltage using the
power supply unit.
1. Switch on the D750.
i
The first time that you start Windows or after you
select the Windows language preference, the screen
will remain black for up to four minutes. During this
time, you cannot tell that the D750 is turned on.
!
Never turn off the D750 during this time! Wait until
the Windows start screen appears.
2. After switching on for the first time, use the lan-
guage selection menu to select the Windows operat-
ing system language and follow the message.
i
There is no provision for subsequent alteration of the
Windows operating system language. Should this nev-
ertheless become necessary, the language selection
menu can be re-started under "Start >> All programs
>> Tools >> Localization".
Initial commissioning
Fitting the storage battery
Connection
Configuration of the operating sys-
tem
Bosch Automotive Service Solutions S.r.l.