1.4
Product description, electric pump
i
Important:
Read and follow the separately enclosed
operating and maintenance instructions
with the declaration of conformity from
the pump manufacturer.
The 12 V, 24 V or 230 V self-priming electric pump
is an electrically driven pump with bypass valve
used to pump and dispense diesel fuels and similar
media from reservoir tanks.
When starting with an empty suction pipe and
partially filled pump, the electric pump is able to
draw in liquid from a maximum height difference of
2 metres.
The pump motor is equipped with thermal overload
protection against overheating and a 12 V/24 V
circuit fuse.
2. Technical data
2.1
Filling station
Capacity (l):
Dimensions [cm]
- Length:
- Width:
- Height:
Weight when empty [kg]:
Total weight when full [kg]:
Environmental conditions:
Operating temperatures: -10°C to +40°C
2.2
Pump
Electric pump with automatic nozzle
Voltage (tolerance) [V]:
Fuse [A]:
Power [W]:
Output (max.) [l]
Output pressure (max.) [bar]
Nozzle connection female thread with swivel joint
['']:
Delivery spout diameter [mm]:
24
For identification of the pump, see the type plate
on the pump or the operating manual of the pump.
Permissible ambient temperatures:
-10°C to +40°C
Permissible media temperature:
-10°C to +40°C
Permissible operating time:
30 minutes at maximum back pressure.
maximum 2 minutes under bypass conditions.
i
Important:
Prolonged dry operation can destroy the
pump.
i
Important:
When connecting to the electricity supply,
always use the correct voltage.
Basic
978
130
112
118
123
1246
12 V DC (± 5%) 24 V DC (± 5%)
50
500
85
1.25
Premium
978
130
112
118
145
1268
230 V DC (±
5%)
30
16 (on site)
420
500
70
72
1.5
2
1
23

Publicidad