10.1.g - Replacing the fuses (Fig. 23)
WARNING:
Replace the blown fuse with one with the
same amperage.
-
Remove the plug (1) from the socket (2).
-
Remove the cover (3) to access the fuses.
Fuse (4) - 7,5A
Control panel protection.
Fuse (5) - Green 30A
Brush rotation motor protection.
Fuse (6) - Red 40A
Aspirator motor protection
-
Put the cover (3) back on.
-
In order to replace the fuse (7) on the
positive pole of the battery, do the follow-
ing:
WARNING:
Check that the recovery tank and the
clean water tank are empty.
-
Disconnect the plug (8).
-
Remove the split pin (9) and lift up the
tanks (10), using the handle (11) until
they are completely overturned.
Fuse (7) - 75A
Battery fuse.