Depth of drive adjustment
Turn the depth of drive
adjustment knob up or down to
change the driving depth.
NOTE: Drive a test nail after
each adjustment until the
desired depth is set.
LED worklight
NOTE: The LED worklights will
be activated when pressing the
on/off trigger or pushing the
workpiece contact.
NOTE: The LED Worklights
provide feedback to indicate
whether the tool is functioning
properly (See troubleshooting).
Removing a jammed nail
Try to operate the tool for two
more times to confirm the nail is
jammed.
NOTE: Before removing a
jammed nail, pull the magazine
release button (See Fig. C1)
down and remove all the nails.
WARNING: Always
remove the battery pack
first and wear safety gloves.
• Pull the magazine release
button down, adjust jammed nail
to the horizontal position and
make the jamed nails away from
the nailer (See Fig. H1).
• Pull up on the tool free jam
release and unhook the latch.
(See Fig. H2).
• Make sure the tip of the driving
mechanism is in the initial
position, if not, insert a flat head
screwdriver into the tip of the
driving mechanism and push
back.
• Remove any bent nails (See
Fig. H3).
• Close the jam release and
latch.
• Reinstall finish nails and
reactivate the tool.
6. MAINTENANCE
Remove the battery pack from the tool before
carrying out any adjustment, servicing or
maintenance.
There are no user serviceable parts in your power
tool. Never use water or chemical cleaners to clean
your power tool. Wipe clean with a dry cloth. Always
20V Cordless 16 Gauge Finish Nailer
store your power tool in a dry place. Keep the motor
ventilation slots clean. Keep all working controls free
of dust. Occasionally you may see sparks through the
ventilation slots. This is normal and will not damage
See Fig. F