Indicator Led's; Information Menu - Hayward AquaRite AQR-PRO-75LSE Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 35
SETTINGS: Push the SETTINGS button to enter the Settings Menu.
CURSORS (+, -, <, >): Use these buttons to scroll through submenus, make selections and adjust values.

Indicator LED's

RUN/STOP: When illuminated, the AquaRite Pro LS is in automatic mode and will produce chlorine based on the
desired output % or ORP setting (when AQL-CHEM is used). When the LED is off, the AquaRite Pro LS has been
manually turned off. It will not produce chlorine until RUN has been selected.
SUPER CHLORINATE: When illuminated, the Super Chlorinate feature is active.
CHECK SYSTEM: When Check System is illuminated, an error has occurred that requires attention. Refer to the
Troubleshooting section of this manual for possible errors and solutions.

Information Menu

The Information Menu displays valuable system and pool information. The AquaRite Pro LS will default to displaying
a portion of the Information Menu when no buttons have been pushed for 2 minutes. The unit will automatically scroll
through several status displays. To access all of the Information Menu items, push the INFO button on the front panel.
Advance through the various menu items using the "<" or ">" buttons. A list of the Information Menu items is shown below.
If ORP Auto Sensing is not used
No Function
Chlorinator
50 %
Move to previous/next menu item
No Function
Super Chlorinate
Move to previous/next menu item
22:15 remaining
The AquaRite Pro LS desired output % is shown here. If Super Chlorinate is active, the display will show
the time remaining until the AquaRite Pro LS will return to the desired output %. This menu is disabled if
an AQL-CHEM is used and ORP Auto Sensing is enabled (see AQL-CHEM manual).
If AQL-CHEM is used
No Function
pH 7.5
(On)
Move to previous/next menu item
ORP 700 mV
(On)
This display will be shown only if chemical sensing is enabled. This display shows both pH and ORP
levels/status when chemistry sensing is enabled via the Chemistry Configuration Wizard (requires the
use of AQL-CHEM Sensing Kit). The AquaRite Pro LS will refer to these levels to determine how much
chlorine to generate (ORP) and how much acid to dispense (pH). Refer to the AQL-CHEM manual for
specific information about these levels as well as the recommended ranges.
Press to switch chlorinator operation to opposite polarity (15 second delay)
+23.45
+6.75A
Move to previous/next menu item
29°C
1.5 g/L
+/- 23.45V is the voltage applied to the chlorinator cell
+/-6.75A is the current (amps) through the cell
29°C is the water temperature at the cell
1.5 g/L is the "instant" salt level at this time
For the chlorinator to be operating, several conditions must exist: the filter pump must be running,
the flow switch must be detecting flow, the chlorinator setting must be set greater than 0%, the water
temperature at the cell must be between 12ºC and 60ºC, and the salt level must be within the operating
range. If any of these conditions are not met, the chlorinator diagnostic display will tell you the reason.
It's possible to have more than one reason, in which case after you rectify what was displayed the first
time, a second display will appear.
Page 7 of 16
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
AquaRite
Pro LS
®
Rev. D

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Aquarite aqr-pro-50lse

Tabla de contenido