Battery temperature sensor connection diagram
Power line connection
3. CT Connection
Pin definition of CT side
1
8
Pin
1 2 3 4 5 6 7 8
Pin Definition
Pin definition of COM port of inverter side
For CT
connection
CT wiring procedures
Connect one side of communication cable to the inverter COM port (PlN 9 and
Pin 10), connect another side to RJ45 terminal (Pin 1 and Pin 8) and insert it into the RJ45
connector, then insert the CT into the RJ45 connector.
66
Non-polar
DC MCB
1
CT1-1
Pin
9
10
Temperature sensor connection
2
3
4
X
X
X
Pin assignment
CT1_1
CT1_2
Lead-acid battery
5
6
7
X
X
X
RJ45
connector
8
CT1-2