Light/shutter control II
▶ The power circuit to which the device and the load are connected must
be secured with a circuit breaker in accordance with EN  60898-1 (trigger
characteristics B or C, max. 16 A rated current, min. 6 kA breaking
capacity, energy limitation class 3). Installation guidelines in accordance
with the applicable national standards – e.g. VDE  0100, HD  384 or
IEC  60364 – must be observed. The circuit breaker must be easily
accessible for the user and labelled as a disconnecter for the device.
▶ The consumers connected to the relay outputs must have sufficient
insulation.
▶ Observe the technical data, in particular the maximum permissible
switching power of the relay and the type of consumer to be connected,
before connecting a consumer. The device should only be loaded to
the specified power limit. Overloading may result in destruction of
the device, fire or an electrical accident. Among other things, reliable
switching off of the connected consumer cannot be guaranteed.
݅ A 230 volt alternating current power supply is required for this product
(there must be a phase and neutral conductor).
↑Contents
8-750-002-899 | V001 | 06/2024
English | 9