OSE 80-2 / ODE 100-2 / ORE 125-2
Integrated extractor with microfilter box
Push microfilter box all the way onto
the extraction nozzle.
To ensure optimum dust extraction, empty
the microfilter box in good time!
Regularly clean filter element.
Pull microfilter box with a twisting
movement off the extraction nozzle.
Remove cover (bayonet lock) and pull
out together with the filter element.
Tap filter element on a solid surface.
Clean fins with a soft brush.
Empty housing of the microfilter box.
Re-attach microfilter box.
Using an external extraction system
Connect extraction hose to the nozzle.
Follow the operating instructions for the dust
extraction system! Check the attachment!
If required, use an appropriate adapter.
NOTE
To prevent the power tool from sticking
to the surface of the workpiece, set the
suction power on the extractor to a corres-
pondingly low level.
Number of oscillations control
The thumb wheel can be used to steplessly
vary the number of oscillations from 1 (low)
to 6 (high) even while the power tool
is running.
As a result, the grinding speed can
be optimally adjusted to the particularly
material and the working conditions.
Switching on and off
Switch on the power tool (1.):
Press switch on I.
Switch off the power tool (2.):
Press switch on 0.
CAUTION!
Following a power failure, the switched-on
power tool will start running again.