PROGRAMMING THE GRINDER
A. Partial 1 dose counter
B. Select dose 1
C. Select dose 3
D. Partial 3 dose counter
E. Deacreasing key
F. Increasing key
G. Counter partial dose
H. Select continuous dose
I. Displaying time of the selected dose
DOSE REGULATION
4.1
• BackPress a button (B), (L) or (C) to select a dose to set.
• Press buttons (E) or (F) to decrease or increase the dispensing time of the selected
dose up to 5 hundredths of second. If pressed longer, time is increased or decreased
depending on the pression of the button.
4.1.1
LOCKING DOSES REGULATION
Press longer the buttons (E)+(F) to lock the time regulation of dose dispensing. On the
screen, you will see (P).
Press again longer buttons (E)+(F) to unlock.
P
O
N
E
F
I
L. Select dose 2
M. Partial 2 dose counter
N. Alarm on
O. Menu access
P. Locked programming
Q Previous page
R. Next page
S. Access to technical menu
T. Exit menu
Q
R
S
T
U
45