During the Ronin TLs life cycle, periodic inspections and maintenance is required. Some parts will experience
wear and will need to be replaced. See table below for periodic inspection, maintenance check and parts
replacement intervals.
Part Number
Description
Thumbwheel
& optional
1011-114
Anti-Panic
Trigger
1011-117-1
Motor/Gearbox
1011-212-1
Tensioner Knob
Tensioner
1011-106
Assembly
1011-912483-1
Battery Indicator
Cam Cinch
2805-14815
Assembly
Drive Shaft
1011-105
Assembly
Cam Insert,
1011-217
11.5-13.0 mm
1011-102
Guide Block Assy
1011-230
Battery
When returning your Ronin TL to have the required annual service completed or any repairs, please follow the steps
below:
1. Complete a RMA (Return Material Authorization) by visiting roninpowerascender.com/rma. Complete the
form and submit.
2. Safely package products along with a copy of the RMA form.
3. Make sure to package your return securely if you are not shipping back in the original packaging or
Ronin hard case.
14
|
RONINPOWERASCENDER.COM
INSPECTION & MAINTENANCE
Inspection Interval
With battery connected rotate thumbwheel
downward slowly and verify motor increases in
speed. Then rotate thumbwheel slowly back to
neutral position and verify thumbwheel decreases
Daily Prior to Use
motor speed to off. If your device has the Anti-Panic
Trigger option, then verify the trigger springs back
to the start position, when released. Make sure the
thumbwheel does not activate the motor without the
With battery connected rotate thumbwheel down-
ward slowly and verify motor increases in speed.
Then rotate thumbwheel slowly back to the off
position and verify thumbwheel decrease motor
Daily Prior to Use
speed to off in the neutral position. Ensure there is no
debris blocking the air vents in the motor cover and
the motor is free from debris inside. If debris is found
Visually inspect tensioner knob threads are in good
Daily Prior to Use
working condition and lubricated with Teflon grease
Verify tensioner assembly moves up and down
At Servicing
smoothly with operation of the tension knob
Visually verify when battery is connected indicator
Daily Prior to Use
flashes through the indicator lights and then displays
Look into the Ronin TL rope Exit hole and visually
Daily Prior to Use
inspect that Cam Cinch teeth are not clogged with
At Servicing
Will be performed at authorized repair facility
At Servicing
Will be performed at authorized repair facility
At Servicing
Will be performed at authorized repair facility
Daily Prior to Use
Verify battery is not damaged, leaking, or swollen
RETURNING FOR SERVICE
Inspection
Trigger being Squeezed.
blow out using air.
current battery charge
any debris and are not worn
Maintenance
Maintenance
Interval
None
None
None
None
Apply Teflon
None
based grease
None
None
None
None
Use an AWL,
Before
Pick or small
Every Use
file to clean
cinch teeth
None
None
None
None
None
None
None
None
Replacement
Interval
Annually
Inspected
Every 2 yrs.
Annually
Inspected
Every year
Annually
Inspected
Every year
Every year
Every year
Annually
Inspected
Approx. 300
Charges