Ronin TL Information
• Do not use the Ronin TL without the required proper personal
protective equipment (PPE). Not doing so may cause serious
injury or death.
• Inspect all equipment prior to each use.
• Only use approved static ropes with the Ronin TL.
• Each Ronin battery has an over current safety cutoff to prevent lifts
over max safe working load.
• Ronin TL is IP54 rated for light rain and use of wet rope. Do not spray
with direct water stream or use in heavy rain conditions.
• Do not stick any foreign metal objects into the Rope inlet or Rope exit
holes for any reason.
• Stop using the device immediately if you begin to feel tired or if you
experience discomfort or pain in your hands, arms or legs while
operating the device
• Do not cover motor ventilation holes
• This product is recommended for adults 18 years of age and higher.
Children under the age of 18 must be supervised by a trained adult.
Motor
Gearbox
Speed Controller
Thumbwheel
Brake
Rope Diameters
Max Rated Power
Mass
Speed
Operating Temp
Sound Level
Vibration Level
Max Capacity
Operational Humidity
Operating Barometric Pressure
Storage Temperature
Storage Humidity
4
|
RONINPOWERASCENDER.COM
PRODUCT SAFETY
Ronin TL Technical Specifications
48 VDC nominal
87amps (15 secburst)
275º F (135º C) max operating Temp
6480 rpm
5.42N-m continuous torque
32:1 reduction
Pulse Width Modulation (PWM)
150 amps max
60VDC Max
.381k ohm
60º rotation
Manual Operations Via Brake Handle
Static Rope 11.5mm to 13 mm
Approximately 2.160 Killawatts
Approximately 19lbs.
Variable at Approximately 0.50 –1.5 ft/sec (0.15 -0.46m/sec)
32º F –104º F (0º C –40º C)
83.1 dBa
6.9 m/s2
400 lbs. (181 kg) (1.78 kN) Max load or 1 Person Max
0 –85 %
29.9 in. Hg –7.04 in. Hg (101 kPa –23.8 kPa)
-4º F –113º F (-20º C –45º C) Less than 1 month
-4º F –95º F (-20º C –35º C) Less than 6 months
≤ 85% Less than 1 month
≤ 70% Less than 6 months