Press the steam plate against the wall for a few seconds.
Determine what the shortest time is to remove the wallpaper. The faster you
work, the more energy you can save.
•
Move the steamplate to the section immediately next to where you have just been
working and use a wallpaper scraper to remove the section that has just been steamed
(Fig. 6).
•
You may need to leave the steamplate against the wall for longer periods with some
papers or re-steam if not completely removed.
9. Refilling
The unit will operate for approximately 78 minutes (UK/EU) and 95 minutes
i
(AUS) before requiring refilling (the water level indicator lights up).
You must never allow the unit to boil dry. There is a safety thermal cut-out
device fitted to the unit. If the unit is allowed to boil dry this will operate and
prevent further use.
•
Switch the unit off and allow it to cool for at least 5 minutes.
Beware of Steam! The Steam is very hot - wear gloves and keep face clear.
•
Open the lid, hold the water tank by the sides and pull it out (Fig. 3).
•
Place the water tank on a flat surface with the tank opening facing upwards, unscrew
the tank cap and fill with clean water (no hot water). (Fig. 4). Do not use additives - do
not overfill.
10. Descaling
Regular descaling is key to your steamer functioning properly. The
i
descaling indicator serves as a guide (depending on the hardness of
the water, earlier or later descaling may be advisable). Units which are
defective due to a lack of descaling are excluded from the guarantee!
Limescale deposits on the heating element act like an insulating layer and
increase energy consumption. Check the heating element visually at regular
intervals and descale at an early stage.
•
Using standard descaling liquid (citric acid recommended) or tablets, fill a jug with 1.0
litres of water.
•
Add correct amount of descaler following manufacturer's guidelines and mix thoroughly.
•
Hold the water tank by the sides and pull it out (Fig. 3).
24