14. Correction of Malfunctions
Malfunction
Malfunction
The steam
wallpaper
stripper is not
working
26
Cause
Cause
•
Heating element covered in
limescale
•
Malfunction (Descale and Refill
flash and an acoustic signal
sounds)
•
Too little water in tank. A safety cut
out is fitted to prevent overheating
of element if there is little water in
tank.
•
Unit at an angle, heating element is
not in water.
•
Usage of an extension lead
•
Overpressure valve triggered (e.g.
due to calcification or kinked/
clogged hose)
SteamForce Speed Pro
Remedy
Remedy
•
Clean
•
Check the unit (tank, hose)
for leaks. Check if the float
is stuck. Check the heating
element for scale build-up.
Check / clean the filter in
the tank cap.
•
Check the heating element
and descale if necessary.
Fill with more water. Wait 2
minutes. Refill will reset the
cut-out element.
•
Move unit into horizontal
position.
•
Check that the extension
lead is rated at minimum of
13 Amps and fully unwound.
•
Let the device cool down
and eliminate the cause (e.g.
descale and clean hose)