Table 2. Reliable Motor Test Requirements
Determine the Motor Connection
1. Connect the alligator clips to the other end of
the test leads.
2. Connect the alligator clips to the motor
connections, L1 to U, L2 to V, L3 to W.
3. Press the ON/OFF button. The green ON indicator
shows that the instrument is ready for testing.
4. Turn the motor shaft half a revolution towards
the right.
09
All manuals and user guides at all-guides.com
Note
The bottom of the apparatus should be oriented
towards the drive shaft . See the Orientation
Symbol on the apparatus.
Either the Clockwise or Counter Clockwise Rotary
indicator illuminates showing the type of rotary
field direction present.
10