NOTE:
If the test leads are open or the resistance of the circuit is over 400Ω, "OL" will
appear on the LCD. "OL".

4.18 Measuring capacitance

Beware of Electrocution. To avoid electric shock, make sure that the
capacitors have been fully discharged before measuring the capaci-
tance of a capacitor..
• Plug the black test lead into the COM jack and the red test lead into the
INPUT jack.
• After fully discharged the capacitor, connect the test leads to the two ends of
the capacitor for measurement.
• Take the reading on the LCD.
NOTE:
It may take some time (about 30 seconds for the 400 µF and
4000 µF range) for steady readings when measuring high capacity.
5. MAINTENANCE

5.1 Replacing the batteries

To avoid electric shock, make sure that the test leads have been clearly
move away from the circuit under measurement before opening the
battery cover of the meter.
• If the sign "
" appears, it means that the batteries should
• be replaced.
• Loosen the fixing screw of the battery cover and remove it.
• Replace the exhausted batteries with new ones.
• Put the battery cover back and fix it again to its origin form.
WARNING
WARNING