Electrical Installation
WARNING
9
The electrical connection of the appliance must be
carried out by a qualified electrician.
CAUTION
9
Before installing, turn off power supply at the service
panel. Lock service panel to prevent power from
being turned on accidentally.
WARNING
9
Local codes may vary; installation, electrical
connections and grounding must comply with all
applicable local codes.
If local codes permit grounding through the electrical
supply neutral, connect both the white neutral wire and
the bare ground wire from the hood to the white neutral
electrical supply wire.
Three-wire 120 V Connection
Remove the cover from the field wiring compartment with
a phillips screwdriver. Feed the power supply cable
through the electrical knockout.
Connect the power supply cable to the rangehood
cable:
Connect white wire from hood to white wire from
▯
power supply in junction box.
Connect black wire from hood to black wire from
▯
power supply in junction box.
Connect green or bare neutral wire from power supply
▯
to ground wire nut in junction box.
WARNING
9
RISK OF ELECTRIC SHOCK
Do not under any circumstances damage or remove the
green/yellow wire. Non-adherence can cause deadly
injuries or electric shock.
The conduit cable, where connected at the hood, flexes.
To maintain serviceability, the flex conduit must not be
shortened and should be routed to permit temporary
removal of the hood.
Using the 4 holes provided, screw the field wiring
compartment to the wall or cabinet as dictated by your
power supply cable location (screws not provided).
Replace the cover.
15