IMPORTANT SAFETY INSTRUCTIONS
9
READ AND SAVE THESE INSTRUCTIONS
INSTALLER: LEAVE THESE INSTRUCTIONS WITH THE
I M P O R T A N T
S A F E T Y
I N S T R U C T I O N S R E A D
A N D
S A V E
T H E S E
I N S T R U C T I O N S
APPLIANCE AFTER INSTALLATION IS COMPLETE.
IMPORTANT: SAVE THESE INSTRUCTIONS FOR THE
LOCAL ELECTRICAL INSPECTOR'S USE.
WARNING
If the information in this manual is not followed exactly,
fire or shock may result causing property damage or
personal injury.
WARNING
Do not repair, replace or remove any part of the
appliance unless specifically recommended in the
manuals. Improper installation, service or maintenance
can cause injury or property damage. Refer to this
manual for guidance. All other servicing should be done
by an authorized servicer.
WARNING
WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:
Installation work and electrical wiring must be done by
▯
qualified person(s) in accordance with all applicable
codes and standards, including fire-rated construction.
Sufficient air is needed for proper combustion and
▯
exhausting of gases through the flue (chimney) of fuel
burning equipment to prevent back drafting. Follow the
heating equipment manufacturer's guideline and safety
standards such as those published by the National Fire
Protection Association (NFPA), and the American
Society for Heating, Refrigeration and Air Conditioning
Engineers (ASHRAE), and the local code authorities.
When cutting or drilling into wall or ceiling, do not
▯
damage electrical wiring and other hidden utilities.
Ducted fans must always be vented to the outdoors.
▯
WARNING
The applicable regulations of the energy supply
companies and the regional construction regulations
must be observed when installing the hood.
4
WARNING
RISK OF FIRE
Grease deposits in the grease filter can catch fire. Never
work with a naked flame near the appliance (e.g.
flambéing). Install the unit near a heat-producing
appliance for solid fuels (e.g. wood or coal) only if there
is a closed, non-detachable cover. There must be no
flying sparks.
WARNING
RISK OF FIRE
Operating several gas burners at the same time gives
rise to a great deal of heat. The ventilation appliance may
become damaged or catch fire. The ventilation appliance
must only be combined with gas burners that do not
exceed the maximum total output of 61,000 BTU/hr
(18 kW). If 41,000 BTU/hr (12 kW) is exceeded, the
local regulations concerning room ventilation, room size,
and combination with ventilation devices in exhaust and
recirculating operation must be followed.
WARNING
To reduce risk of fire and to properly exhaust air, be sure
to duct air outside. Do not vent exhaust air into spaces
within walls, ceilings, attics, crawl spaces or garages.
WARNING
To reduce the risk of fire, use only metal ductwork.
WARNING
When the hood is operated in exhaust-air mode
simultaneously with a different burner which also makes
use of the same chimney (such as gas, oil or coal-fired
heaters, continuous-flow heaters, hot-water boilers) care
must be taken to ensure that there is an adequate supply
of fresh air which will be needed by the burner for
combustion.
Safe operation is possible provided that the under
pressure in the room where the burner is installed does
not exceed 4 Pa (0.04 mbar).
This can be achieved if combustion air can flow through
non-lockable openings, e.g. in doors, windows and via
the air-intake/exhaust-air wall box or by other technical
measures, such as reciprocal interlocking, etc.