Do not run the sprayer dry for more than 30 seconds. Doing so could
damage the pump packing seals.
Protect the internal drive parts of the sprayer from water. Openings in
the cover allow for air cooling of both the mechanical parts and
electronics. If water enters these openings, the sprayer may
malfunction or be permanently damaged.
Prevent corrosion or freezing of the pump to avoid damage. Fluids that
freeze within the sprayer or High-Pressure hose will cause permanent
damage. Always store the sprayer with a m ulti-purpose light machine oil
such as sewing machine oil or ISO 22 oil added to the sprayer pump as
described in the section titled Storing the Sprayer.
SPRAYTIP SELECTION
Spray tips are numbered so that:
SPRAYTIP SELECTION
•The first digit, when multiplied by two, gives the spray width in inches (with the
spray tip 1 -foot (30cm) away from the surface being sprayed).
•The last two digits specify the orifice size in thousands of an inch (Note: a larger
orifice increases paint flow).
•The following are recommended spray tip orifice sizes for varying types of coating
material: Lacquer & Stain: 0.007" — 0.013"
0.015" — 0.021"
CAUTION
Enamel: 0.011" — 0.015" Acrylic: