1.0
GENERAL INFORMATION
This equipment is a compressed air plasma cutting unit for manual
cutting operations on all conducting materials.
1.1
UNIT COMPOSITION
The equipment, is fitted with:
1.
One 6 meter long 4 x 2.5mm primary cable
2.
One 3 meter long 16 mm secondary cable fitted with a ground
connection
3.
One 5 meter long compressed air pipe
4.
1 plastron-skirt assembly
5.
1 set of wearing parts
6.
1 equipment operating and maintenance manual
1.2
APPROVED TORCH REFERENCES
- OERLIKON - CITORCH P40C
- TECMO – PT100
2.0
DESCRIPTION AND TECHNICAL SPECIFICA-
TIONS
2.1
DESCRIPTION
Figure 1.
GENERAL INFORMATION
Figure 2.
1.
ON/OFF switch
2.
Current/Thickness display
3.
Current adjustment encoder
4.
Reset and mode selection switch
5.
Workpiece connector
6.
Cutting mode indicator light
7.
Restrike mode indicator light
2
8.
Gouging mode indicator light
9.
Pressure adjustment mode indicator light
4
10. Fault light
11. Regulator-filter pressure setting
12. Air inlet pipe
6
13. Power supply cable
14. Torch connector
7
2.2
DATA PLATE
8
Three phase supply
Frequency
9
Effective consumption
Maximum consumption
10
Open circuit voltage
Cutting current
3
Duty cycle 50%
Duty cycle 60%
Duty cycle 100%
5
Protection class
14
Insulation class
Weight
Dimensions
European Standards
Ingress protection (IP) ratings for electrical enclosures
Code letter
First number
Second number
3 EN
TECHNICAL SPECIFICATIONS
PRIMARY
SECONDARY
IP
Equipment protection
Protection against solid objected with diame-
2
Protection against vertically falling drops of
1
water, e.g. condensation
Protected against sprays of water up to 60°
3
S
Device standing still during water test
11
12
1
13
230 V
400 V
50 Hz
15 A
16.5 A
21.2 A
23.3 A
250 V
243 V
20 A ÷ 65A
65 A - 106 V
60 A - 104 V
40 A - 96 V
50 A - 100 V
IP 23 S
H
25 Kg
435 x 235 x 380 mm
EN 60974.1
EN 60974.10
Ø≥
ter
12.5mm
from the vertical