C 210 ECO - GSR 210 Condens
MC35E/45/65/90/115 - GMR4000Condens
DTG(E)130 - 35/45/65/90/115 Eco.NOxPlus - GSR140-35P/45/65/90/115Condens
GR12
Alarm and control module AM 35
Used in association with condensation boilers, the AM 35 alarm and
control module is used:
- the connection of an external signalling sytem (warning light or
acoustic signal) to indicate boiler anomalies and either :
- to control an external safety valve
- the connection of a flue damper motor
The alarm output is a normal-open contact with the C 210 ECO /
GSR 210 Condens and a normal-closed contact with the
MC 35E-90 / GMR4000Condens / DTG(E)130 - 35/45/65/90/
115 Eco.NOxPlus / GSR140-35P/45/65/90/115Condens.
Alarm- en bedieningsmodule AM 35
In combinatie met de condensatieketels is het volgende mogelijk met
de alarm- en bedieningsmodule AM 35:
- de aansluiting van een externe signalering (controlelampje of
geluidssignaal) in geval van storing in de ketel, en :
- de bediening van een externe veiligheidsklep
- de aansluiting van een motor van een afsluitklep
De alarmuitgang is een normaal-open contact bij de
C 210 ECO / GSR 210 Condens en een normaal-gesloten
contact bij de MC 35E-90 / GMR4000Condens / DTG(E)130 -
35/45/65/90/115 Eco.NOxPlus / GSR140-35P/45/65/90/
115Condens.