Descargar Imprimir esta página

Bio Bronpi Radiofrecuencia Serie Instrucciones De Instalación, Uso Y Mantenimiento página 43

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

9.5
USER MODE
Below is a description of the control normal operation according to the available
functions.
Before the ignition of the stove or insert, the control shows the following screen (see
drawing D85): It is showed up the "off" state, the room temperature, the established
working power and the current hour.
9.5.1
STOVE OR INSERT IGNITION
In order to ignite the stove, press button no. 3 during a few seconds. The control will
show the ignition state as follows (see drawing D86):
The maximum length of the ignition phase is 20 minutes. After this time, if there is no
visible flame, the stove will automatically go into the alarm state and the control will
show the message "Ignition Failure."
9.5.2
STOVE OR INSERT IN OPERATION
The hot air fan will start when the smoke temperature reaches a minimum. Auxiliary fans
(in case of models of channelling stoves Agatha Extra, Alicia Extra, Clara Extra, Cleo
Extra and Olivia Extra) will start only if enabled.
In this moment, the stove or insert is correctly burning. After this, our stove will be
working normally (see drawing D87).
The control shows the ambient temperature in the room.
9.5.3
CHANGE OF THE SET-POINT ROOM TEMPERATURE
In order to modify the setting room temperature, please press button 4 and then buttons
1 and 2 to increase or decrease it respectively (see drawing D88).
9.5.4
ROOM TEMPERATURE REACHES TEMPERATURE FIXED BY THE USER
When the ambient temperature (of the room) reaches the value set by the user or the
smoke temperature reaches a too high value, the stove or insert will automatically
operate at one lower power, it means that modulates in power. See drawing D89.
Remember that if it is activated "stand-by mode", when the ambient temperature
reaches the value set by the user plus a differential (2ºC) the stove or insert will be
automatically turned off and will be on hold until the ambient temperature falls to
the set temperature minus a differential (2ºC). After that, the stove or insert restarts
automatically.
9.5.5
BURNER CLEANING
While the stove or insert is working normally, some automatic cleanings of the burner
take place in several minutes intervals. This process consists of cleaning the rest of
pellet remaining in the burner in order to guarantee a proper working of the stove or
insert (see drawing D90) and it takes several seconds.
9.5.6
TURNING OFF THE STOVE OR INSERT
In order to turn off the stove or insert, press button no.3 during a few seconds. Once it
has been turned off, it will start the final cleaning stage, in which the pellet supply stops
and the smoke extractor will be working to the maximum speed. This stage would not
finish until the stove or insert has reached the appropriate cooling temperature (see
drawing D91).
9.5.7
STOVE OR INSERT TURNED OFF
When the stove is turned off, the control shows the following information (see drawing
D92):
9.5.8
RE-IGNITION OF THE STOVE OR INSERT
When the stove or insert is turned off it would not be possible to restart it up until some safety time goes by and the
stove or insert is cold enough. If you try to start-up the stove, the display will show up the following information (see
drawing D93):
10 ALARMS
In case of an anomaly during the operation, the electronics of the stove or insert intervenes and highlights the
irregularities that have ocurred in the different working phases, depending on the type of fault.
Every alarm situation blocks the stove or inserts to be automatically blocked. By pressing button 3 we can unblock
it. Once the stove or insert has reached the appropriate cooling temperature, the user can restart it up.
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
14:24
21º C
OFF
MENU
15:18
21º C
WORKING
MENU
16:40
27º C
WORKING
MODULATE
MENU
21:10
23º C
FINAL
CLEANING
MENU
42
14:24
P-2
21º C
P-2
IGNITION
MENU
D85
21º C
P-3
SET TEMPER
ROOM
MENU
D87
16:40
P-2
22º C
P-2
BURNER
CLEANING
MENU
D89
21:28
P-3
23º C
P-3
OFF
MENU
D91
STAND-BY
COOL
MENU
RADIOFREQUENCY SERIES
D86
D88
D90
D92
D93

Publicidad

loading