Best CP55IQ Manual De Uso página 5

Ocultar thumbs Ver también para CP55IQ:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

1. INSTALL DUCTWORK AND ELECTRICAL WIRING
1.1 N
-D
I
ON
UCTED
NSTALLATION
CP55IQ Series power packs may be non-ducted. ANKCP55 non-duct kit must be installed (sold separately).
1.2 D
I
UCTED
NSTALLATION
For a CP57E Series power pack, either an exterior blower or in-line blower must be used. The CP57E Series power pack must be
installed with blower models ILB3, ILB6, ILB9, ILB11, EB6, EB9, EB12 or EB15 only. Other blowers cannot be substituted (blowers
sold separately.) Plan where and how the ductwork will be installed.
If installing exterior or in-line blower, refer to instructions packed with blower and follow steps 1 up to 7, 11, 13 and up of
this manual.
Install proper-sized ductwork, elbows and roof or wall cap for the type of blower you are installing. If installing CP55IQ Series power
pack, use 8" round ductwork and if installing CP57IQT or CP57E Series power pack, use 10" round ductwork. Use metal foil duct
tape to seal duct joints.
NOTE: It is recommended that there be a minimum of 6" of straight duct from the hood to an elbow for 8" duct and 12" for 10" duct.
1.3 A
I
LL
NSTALLATIONS
The minimum power pack distance above cooktop must not be less than 24''. A maximum of 30" above cooktop is
recommended for best capture of cooking impurities.
Distances over 30" are at the installer and users discretion.
Run 3-wire power supply cable to installation location. Its length should extend at least 4 feet below the bottom of the custom hood.
ROOF CAP
8" ROUND ELBOW FOR CP55IQ OR
10" ROUND ELBOW FOR CP57IQT
WALL
CAP
24" TO 30"
ABOVE COOKING SURFACE
HH0201A
CP55IQ (
CP57IQT (
OR
T
YPICAL
(CP55IQ S
ERIES POWER PACKS ONLY
(A
)
LL POWER PACKS
8" ROUND DUCT FOR CP55IQ OR
10" ROUND DUCT FOR CP57IQT
10" IN LINE
VERTICAL DAMPER FOR CP57IQT
8" ROUND ADAPTER & DAMPER
FOR CP55IQ OR
10" ROUND ADAPTER FOR CP57IQT
POWER PACK
)
SINGLE INTERNAL BLOWER
)
DUAL INTERNAL BLOWER
D
UCTWORK
EXTERIOR BLOWER
EXTERIOR
BLOWER
HH0115A
CP57E E
XTERIOR
)
(except ILB3, 8'' ROUND DUCT)
IN-LINE BLOWER
24" TO 30" ABOVE
COOKING SURFACE
HH0114A
CP57E
ILB11 I
OR
(
BLOWER LOCATION IS SHOWN FOR REFERENCE ONLY
10" ROUND DUCT
10" ROUND ELBOW
POWER PACK
24" TO 30"
ABOVE
COOKING SURFACE
B
T
D
LOWER
YPICAL
UCTWORK
5
ROOF CAP
10" ROUND DUCT
WALL
CAP
POWER PACK
M
ILB3, ILB6, ILB9
WITH
ODEL
-
B
T
D
N
LINE
LOWER
YPICAL
UCTWORK
)

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Cp57iqt

Tabla de contenido