INSTALLING THE BRUSHES
CAUTION!
Turn the key switch off (O) and remove the key, before changing the brushes, and before opening any access panels.
1
Make sure the Brush Deck (7) is in the RAISED position. Make sure the Key Switch (A) is off (O).
2
If using pads, install the pads on the pad holders.
3
See Figure 2. Unlatch the right and left Brush Housings (8) at the Latch (AA). Slide each brush housing off of the scrub deck.
4
Put a brush or pad driver (BB) under the brush motor plate.
5
Align the slots in the brush gimbal with the lugs on the motor Gimbal (CC).
6
Pull the brush up until the gimbal locks.
7
Repeat steps 4, 5 & 6 to install the second brush or pad driver.
To Remove:
1
Make sure the Brush Deck (7) is in the RAISED position. Make sure the Key Switch (A) is off (O).
2
Remove the Brush Housings (8).
3
Push down on two sides of the brush or pad driver until the gimbals release.
FIGURE 2
ENGLISH / A-11
FORM NO. - 56041987 - 34 RST - A-11