This user manual includes information to operate your device and precautions for your safety. To get the best of your
equipment please read carefully before use.
GENERAL DESCRIPTION
NEOSTART devices are designed for charging and starting 12V (6 element) and 24V (12 element) lead acid batteries
(electrolyte):
Assembly - handle and wheels (only for NEOSTART 420 and 620) :
POWER SUPPLY
Check that the power and protection (fuse and / or circuit breaker) are compatible with the current required. The
appliance must be positioned so that the plug socket is accessible.
They must be connected to a single phase 230V socket with EARTH protected by a 16A circuit breaker.
CONNECTION AND DISCONNECTION
IMPORTANT! Before connecting to a battery, check that the device is not connected to the power supply and the switch
is OFF (if any).
Secondly, check the polarity of your battery.
Warning: The cables must not be pinched or in contact with hot or sharp surfaces
Starting and Charging a battery connected on the vehicle:
Where the negative pole of the battery is connected to the vehicle chassis
• Connect the red clamp to the positive pole of the battery.
• Connect the black clamp to the vehicle chassis, ensure it is not close to fuel lines and the battery.
• Connect the device to the mains.
• After use, turn the switch to OFF (if any), then disconnect the charger from the mains supply then disconnect the black
clamp and finally the red clamp.
Some vehicles have the positive pole of the battery connected to the chassis, in this case:
• Connect the black clamp to the negative terminal of the battery.
• Connect the red clamp to the vehicle chassis, ensure it is not close to fuel lines and battery.
• Connect the device to the mains.
• After use, turn the switch to OFF (if any), then disconnect the charger from the mains supply then disconnect the red
clamp and finally the black clamp.
Charging a battery not connected to the vehicle:
• Connect the red clamp to the positive battery terminal and then the black clamp to the negative terminal of the battery.
• After use, turn the switch to OFF (if any), then disconnect the charger from the mains supply then disconnect the red
6
NEOSTART 320 / 420 / 620
Neostart 320
Neostart 420
Neostart 620
Charging
40 - 400 Ah
25 - 600 Ah
45 - 900 Ah
Starting
35 - 120 Ah
35 - 160 Ah
45 - 200 Ah
EN