Possibilities
Standard functioning (without Ecos modules):
In the basic version during stand-by a point (.) will be
shown on the display. As soon as the main time is
connected the display will change into two hyphens (--).
The maximum period of time to be programmed in the
®
MicroTimer
is 15 minutes. The main time starts after
pressing the timer-key, after inserting a coin or by means
of a continuous external drive. The MicroTimer
programmable. It may be chosen between the standard
"continue" output, which means that both relays are
activated during main time, and a "pulse" output, which
means that a pulse is generated at the beginning and the
end of the main time. The operator may choose either to
allow the creation of a pause during the main time or not.
If a pause is allowed, it can be created by pressing the
Start/Pause key. The operator can also choose between
interrupting and continuing the main time during the pause
mode.
Extra functioning (with all Ecos modules):
®
The MicroTimer
can be activated with three freely
programmable time-segments. The duration of these time-
segments can be set at 0 to 255 minutes. The
®
MicroTimer
starts with a prior time. During the prior time
the length of the main time will be shown intermittently on
the display. During the prior time it is possible to reduce
the main time if necessary. The prior time can also be
bypassed so that the main time will start automatically.
During the main time the remaining time will be shown on
the display. When activating a pause a buzzer signal may
be generated. Another possibility consists of the
automatic main time adjustment based on the progression
of the service counter. The main time is automatically
followed by the post time. During the post time "Cl" (cool)
is displayed. After the post time it is possible to activate a
clean function, in this case "CL" is displayed intermittently.
This clean function inhibits the MicroTimer
there is an "after start" function by means of which an
extra main time of 30 seconds can be given at the end of
the whole session.
Registration facilities, as for example start, running time
and service counters can also be used. The start and
running time counters may either be activated as
counters, which can be reset, or as cumulative counter,
which can not be reset. Automatic representation of the
Running time counter is affected by pressing the Stop key
during 3 seconds. The service counter generates a SR
(service message) on the display.
®
output is
®
. Furthermore,
®
MicroTimer
2400 Version 4.0 05-11-2007
-
www.inepro.com
Start by means of;
- Timer key
- Insertion of coin
- External drive
Display indication
- during stand-by
one point (.)
Main time
- during operation
0-15minutes
two hyphens (--)
Pause facility
2 possibilities of
programming the
output
Simple reading of the
service counter
Quick start function
Prior time
Main time reduction
0-255minutes
Real time indication
Minimum and
maximum start control
Main time
0-255minutes
Buzzer signal during
pause
Automatic main time
adjustment
Post time
Clean function
0-255minutes
After start function
Service counters
Complete registration
facilities
Simple reading of the
running time counter
-
13