Settings
Function FB, Running time counter (reset possible)
The running time counter is an electronic counter, which registers cumulatively the number of minutes the main
channel, relay 1, has been operative. The main channel relay 1 is only active during the main time of the
®
MicroTimer
. It is possible to scroll the counters by pressing the Start/Pause key (Up). The 6-digit counter is
read back to front, as follows;
first counter
1
= value "1",
second counter
2
= value "3",
third counter
3
= value "7",
forth counter
4
= value "5",
fifth counter
5
= value "0",
sixth counter
6
= value "0",
In this example the total running
Resetting the counters
After reading the counters, these can be reset. The reset-procedure is as follows;
1, After having read the count (6X) press the Start/Pause (up) and the Stop (down) keys simultaneously
-
-- (2 hyphens) will appear on the display
2, To reset the counter press the Start/Pause key,
-
"CL" will appear on the display
3, Now press the Start/Pause (up) and the Stop (down) keys simultaneously
-
the counters are reset and the MicroTimer
Note: if necessary, you can also read out the indication on the counter without resetting it during the stand-by
period, to do so, press the Stop key during 3 seconds. The indication of the counters of Function FB will be
represented automatically, but cannot be reset.
Function FC, Start pulse counter (reset possible)
Reading and reset procedure as in function FB. This counter reproduces the number of start pulses.
Function FD, Running time counter (reset impossible)
Reading as in Function FB but this counter can not be reset.
Function FE, Start pulse counter (reset impossible)
Reading as in Function FB but this counter can not be reset. This counter reproduces the number of start
pulses.
Function FF, TAT (Automatic main time adjustment)
Activating this function, the main time is automatically adjusted on the basis of the service counter progression
(F6 & F7). If one of the two service counters is programmed again the TAT function has to be preset again as
well.
Setting "00": TAT function off
Setting "01": TAT function on
Running hours
Prolongation per minute
0 – 49
+ 0 sec p/m
50 – 99
+ 3 sec p/m
100 – 149
+ 5 sec p/m
150 – 199
+ 8 sec p/m
200 – 249
+ 11 sec p/m
250 – 299
+ 14 sec p/m
300 – 349
+ 16 sec p/m
350 – 399
+ 19 sec p/m
400 – 449
+ 22 sec p/m
(ECOS module EM-10)
1
1
2
3
3
7
4
5
5
0
6
0
time amounts to 005731 minutes
®
will automatically resume its function.
(ECOS module EM-10)
(ECOS module EM-12)
Running hours
450 – 499
500 – 549
550 – 599
600 – 649
650 – 699
700 – 749
750 – 799
800 – 849
850 - 899
®
MicroTimer
2400 Version 4.0 05-11-2007
-
www.inepro.com
(ECOS module EM-12)
(ECOS module EM-11)
Prolongation per minute
+ 24 sec p/m
+ 27 sec p/m
+ 30 sec p/m
+ 30 sec p/m
+ 30 sec p/m
+ 30 sec p/m
+ 30 sec p/m
+ 30 sec p/m
+ 30 sec p/m
-
16