Settings
The programmer's stand:
®
The MicroTimer
can be programmed by means of three control keys, which are
integrated in the front panel of the machine. By activating these control keys, the
function menu can be programmed, modified or read. The control keys are marked
on the outside by Start/Pause, Timer and Stop.
ATTENTION!
If dipswitch 1 is in an "OFF" position, all settings can be carried out, If the dipswitch is "ON", tha the settings are
disabled. (Dipswitch 1 is the nearest to the buzzer).
Activation of the function menu:
1) Press the Start/Pause and Stop keys simultaneously when in "stand by";
2) Release both control keys, F1 will be displayed;
3) Scroll to the desired function by means of the Start/Pause (Up) and Stop control keys (Down);
4) Press the Start/Pause and Stop keys simultaneously to read or modify the current value of the selected
function;
5) The value is modified by pressing the Start/Pause key (Up) or the Stop key (Down) ;
6) Quit and confirm the set-value by pressing the Start/Pause key (Up) and the Stop key (Down)
simultaneously. You will now return to the function menu and you can scroll to another function if you wish;
7) Quit the function menu by scrolling to function F0 and pressing the Start/Pause key (Up) and the Stop key
(Down) simultaneously.
Function overview
Function F0, Quitting the function menu
Choosing this function the MicroTimer
Function F1, Main time setting per start pulse
Main time setting for relay 1 per start pulse given. In the standard version this setting may vary from 1 to 15
minutes. By adding "ECOS"
programmed the indication will be displayed intermittently in two parts; first display "1", second display "00".
Function F2, Prior time setting
Before starting the main time, relay contact 2 shall be closed. This setting is programmable up to a maximum of
255 minutes.
Function F3, Post time setting
At the end of the main time, relay contact 2 shall be closed. This setting is programmable up to a maximum of
255 minutes.
Function F4, Maximum amount of start pulses
Maximum amount of start pulses that can be activated to increase cumulatively the total main time. The value of
this setting has to be at least 1.
®
will remain in stand-by to be able to program or to quit the menu.
(ECOS module EM-01)
®
up to 255 minutes can be programmed. If a value of more than 100 minutes is
(ECOS module EM-02)
(ECOS module EM-03)
(ECOS module EM-04)
®
MicroTimer
2400 Version 4.0 05-11-2007
-
www.inepro.com
-